Performance
- Temperature range from ambient +5℃ to 100℃.
- Microprocessor PID control / Automatic tuning / Calibration.
- Powerful circulation system using our patented agitator.
Safety
- Two independently controlled reservoirs merged into a single unit for space saving. (for Dual models)
- Digital LED displays with quick adjustable dial knob. (0.1℃resolution)
- Low-profile design with sloped control panel for easier access and better safety.
Convenience
- Isolated design of heater, and sensor by a baffle plate to protect users and samples against direct contact.
- Complete safety protection system with warning alarms.
- Over-temperature, over-current protection.
- Keypad lock function prevents accidental changes during operation.
Available Accessories & Options
- Transparent Polypropylene Gable Covers - prevent liquid loss due to evaporation, and also protect samples from contamination due to direct dripping of the bath liquid into the samples. The gable type roof accommodates glassware of varying heights.
- Stainless Steel Flat Covers - Made of stainless steel to prevent corrosion and rust. (only for BW-H and BW-B Models)
- Open-rings Covers - Beakers or Erlenmeyer flasks can be placed directly onto the perforated stainless steel half-shelf adjuster or water tank bottom. By adjusting ring size for each glassware, liquid loss due to evaporation is minimized. (only for BW-H, BW-B, BW-G Models)
- Test Tube Racks - Highly durable stainless steel test tube racks feature adjustable angle and tube height support without requiring any base plate. You can easily mount and release test tube racks.
- Spring Wire Racks - Ideal for holding a wide variety of tubes, flasks, and other glassware. All components are made of stainless steel. (for all models)
- Half-shelf Adjusters - Stainless steel perforated sample tray shelves with adjustable height support prevent leaks and guard against rust and contamination. (only for BW-H, BW-B, and BW-G Models)
Digital Model |
BW-05H |
BW-10H |
BW-20H |
Bath volume (L / cu ft)
|
3.5 / 0.1
|
11.5 / 0.4
|
20 / 0.7
|
Working temperature range (℃ / ℉)
|
Amb. +5 to 100 / Amb. +9 to 212
|
Temperature stability 1) (±℃ / ℉)
|
±0.1 / 0.18
|
Dimension
|
Bath opening / depth (W×L, D) (mm / inch)
|
240×136, 150/ 9.4×5.4, 5.9
|
300×240, 200/ 11.8×9.5, 7.9
|
498×300, 200/ 19.6×11.8, 7.9
|
Exterior(W×L×H) (mm / inch)
|
307×216×266 / 12.1×8.5×10.5
|
364×316×318 / 14.3×14.4×12.5
|
564×372×318 / 22.2×14.6×12.5
|
Net weight (kg / lbs)
|
6.5 / 14.3
|
9.5 / 21
|
15.5 / 34.2
|
Electrical requirements (230V, 50 / 60Hz)
|
3.0A
|
4.3A
|
8.7A
|
Cat. No. |
AAH45115K |
AAH45125K |
AAH45135K |
Dual Model |
BW-0505H |
BW-0510H |
BW-1010H |
BW-1020H |
Bath volume (L / cu ft)
|
3.5 & 3.5 / 0.1 & 0.1
|
3.5 & 11.5 / 0.1 &0.4
|
11.5 & 11.5 / 0.4 & 0.4
|
11.5 & 20 / 0.4 & 0.7
|
Working temperature range (℃ / ℉)
|
Amb. +5 to 100 / Amb. +9 to 212
|
Temperature stability 1) (±℃ / ℉)
|
±0.1 / 0.18
|
Dimension
|
Bath opening / depth (W×L, D & W×L, D) (mm / inch)
|
240×136, 150 per chamber
|
240×136, 150 & 300×240, 200
|
300×240, 200 per chamber
|
300×240, 200 & 498×300, 200
|
9.4×5.4, 5.9 per chamber
|
9.4×5.4, 5.9 & 11.8×9.5, 7.9
|
11.8×9.5, 7.9 per chamber
|
11.8×9.5, 7.9 & 19.6×11.8, 7.9
|
Exterior (W×L×H) (mm / inch)
|
590×216×265 / 23.2×8.5×10.4
|
544×316×318 / 21.4×12.4×12.5
|
706×300×318 / 27.8×11.8×12.5
|
844×372×318 / 33.2×14.6×12.5
|
Net weight (kg / lbs)
|
9.7 / 21.3
|
12.4 / 27.3
|
14 / 30.8
|
17.6 / 38.7
|
Electrical requirements (230V, 50 / 60Hz) |
3 & 3A |
3 & 4.3A |
4.3A & 4.3A |
4.3A & 8.7A |
Cat. No. |
AAH47115K |
AAH47125K |
AAH47135K |
AAH47145K |