HI96710 pH, Free Chlorine, and Total Chlorine Portable Photometer

The HI96710 pH, Free Chlorine, and Total Chlorine Portable Photometer combines accuracy and ease of use in an ergonomic, portable design. A user can accurately determine the pH, free chlorine, and total chlorine concentration of water samples using ready made reagents. The HI96710 offers many advanced features including the exclusive CAL Check™ function used for performance verification and calibration of the meter.

Brand: Hanna

Learn more

Go to checkout

The HI96710 portable photometer is for the measurement of pH, free chlorine, and total chlorine. Hanna's portable photometers feature an advanced optical system; the combination of a special tungsten lamp, a narrow band interference filter, and silicon photodetector ensure accurate photometric readings every time. The Hanna exclusive CAL Check™ feature utilizes ready-made, NIST traceable standards to verify both meter validation and calibration. The exclusive cuvette locking system ensures that the cuvette is inserted into the measurement cell in the same position every time to maintain a consistent path length.

 

Features at-a-glance

  • CAL Check™ - Allows for performance verification and calibration of the meter using a CAL Check NIST traceable secondary standard.
  • GLP - Records the date of the last user calibration performed.
  • Built in timer - Ensures the appropriate reaction time is used for the chemical reaction. At the end of the timer the meter will automatically take the reading. This feature ensures consistency across multiple users.
  • Indexing indent on meter - The meter has an indent that allows for a lock and key fit with the cuvette cap. This ensures that the cuvette is indexed consistently (same position) in order to maintain the same path length for accurate results.
  • Cooling Lamp Indicator - It is necessary to maintain a consistent temperature of the optical components in order to maintain a narrow wavelength band of light. This photometer has a cooling lamp indicator that is displayed for a short period of time before each measurement in order to allow the components to cool and obtain the highest accuracy possible.
  • Error messages - Messages on display alerting to problems including no cap, over range and under range readings, and light source error.
  • Auto-shut off - Automatic shut off after 10 minutes of non-use when the meter is in measurement mode. Prevents wastage of batteries in the event the meter is accidentally not turned off.
  • Battery status indicator
  • The instrument has a battery level indicator to display reaming life as follows:
    • 3 lines for 100 % capacity
    • 2 lines for 66 % capacity
    • 1 line for 33 % capacity
    • Battery icon blinks when the capacity is less than 10 %.
  • Units of measure - Appropriate unit of measure is displayed along with reading.

Absorbance Specifications

Light Source tungsten lamp
Light Detector silicon photocell with narrow band interference filter @ 525 nm

Additional Specifications

Range pH (P1): 6.5 to 8.5 pH; Free & Total Chlorine (P2 & P3): 0.00 to 5.00 mg/L (ppm)
Resolution pH (P1): 0.1 pH; Free & Total Chlorine (P2 & P3): 0.01 mg/L under 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy @ 25°C (77°F) pH (P1): ±0.1 pH; Free & Total Chlorine (P2 & P3): ±0.03 mg/L (ppm) ±3% of reading
Method pH (P1): phenol red method; Free & Total Chlorine (P2 & P3): adaptation of the USEPA method 330.5
Auto-off after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Weight 360g (12.7oz.)
Battery Type 9V battery
Dimensions 193 x 104 x 69 mm (7.6 x 4.1 x 2.7”)
Ordering Information HI96710 is supplied with sample cuvettes (2) with caps, 9V battery, instrument quality certificate and instruction manual.
Warranty 2 years