Chloride Combination Ion Selective Electrode - HI4107

HA-HI4107

The HI4107 is a solid state, combination ion selective electrode (ISE) for the determination of chloride (Cl-) in solution. The silver chloride sensing pellet produces a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body. The HI4107 is ideal for a variety of applications in food and beverages, agriculture, and water treatment.

Brand: Hanna

Learn more

Product CodeProduct Product Description Price (Excl gst) Qty Add
HA-HI4107 Chloride Combination Ion Selective Electrode - HI4107 Chloride Combination Ion Selective Electrode - HI4107 Login for price  

Go to checkout

Features at-a-glance

Fixed Sensing Modules - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.

Durable PEI Body - The probe body is composed of durable polyetherimide (PEI) plastic.

BNC Connection - The HI4107 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.

 

The HI4107 chloride ion selective electrode is a complete potentiometric cell that contains a silver/silver chloride (Ag/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver chloride sensing membrane.

Hanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

For the HI4107 to measure chloride accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free chloride ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4107 chloride solid state ISE can measure from 50µM (1.8 mg/L) to 1M (35,500 mg/L).

 

Conversion Table for Cl-

 

Multiply

moles/L (M) to ppm (mg/L)

3.500 x 104

ppm (mg/L) to M (moles/L)

2.857 x 10-5

Type combination
Measurement Range Chloride (Cl-) 1.0M to 5 x 10-5M, 35,500 to 1.8 mg/L (ppm)
Optimum pH Range pH 2 to 11
Temperature Range 0 to 80 °C
Approximate Slope -56 mV
Diameter 12 mm
Overall Length 120 mm
Body Material PEI
Cable coaxial; 1 m (3.3’)
Connection BNC