Enjoy FREE SHIPPING on all orders of FreeStyle Libre from 12th June – 19th July 2020! Simply enter the code FREESHIP in the shopping cart, or at checkout to claim this offer.

FreeStyle Libre Coronavirus (COVID-19) Update - Learn more

X
Menu
Cart
X

Search Website

QUICK ORDER PRODUCTS

If you know the product code enter it here  

Autoranging Benchtop EC/TDS/Salinity Meter with ATC - HI2300

The HI2300 is an auto ranging EC/TDS/Salinity and temperature benchtop meter. The meter utilizes a four-ring potentiometric conductivity probe with platinum sensors to offer versatility over typical amperometric designs.

Brand: Hanna

Learn more

Product CodeProduct Product Description Price (Excl gst) Qty Add
HA-HI2300-02 Autoranging Benchtop EC/TDS/Salinity Meter with ATC - HI2300 Autoranging Benchtop EC/TDS/Salinity Meter with ATC - HI2300 Login for price  

Go to checkout

The HI2300 is a durable benchtop EC/TDS/Salinity and temperature meter that features a four-ring potentiometric probe, one-point calibration, and a USB port for computer connectivity. This meter is auto ranging to choose the appropriate conductivity and total dissolved solids (TDS) range, and can easily be switched to salinity mode to measure from 0.0 to 400.0% NaCl.

Features

Autoranging - In the EC and TDS measurement modes, the HI2300 automatically chooses the optimum measurement scale based on the sample solution to maintain the highest possible accuracy.

Automatic Calibration - EC and TDS are automatically calibrated at one point with a choice of six pre-programmed standards. Salinity is calibrated at one point using the HI7037 100% NaCl standard solution.

Four-ring EC Probe - The HI2300 meter is supplied with the HI76310 platinum, four-ring EC/TDS probe with a built-in temperature sensor that operates over a wide range from 0.00 μS/cm to 500.0 mS/cm*.

Temperature Compensation - Temperature can be compensated for automatically (ATC) or manually (MTC) from -20.0 to 120.0°C, or it can be disabled for actual conductivity or TDS measurements. The temperature correction coefficient, also referred to as β, is adjustable from 0.00 to 6.00 %/°C.

Adjustable TDS Factor - The factor that relates conductivity to total dissolved solids is based on the type of sample being measured. For users to get an accurate determination of TDS based on their unique solution, the TDS factor is adjustable from 0.40 to 0.80.

GLP Data - The calibration data including date, time, standards used, offset and cell constant can be accessed at any time along with the current measurement by selecting the Good Laboratory Practice (GLP) display option.

Data Logging - The log-on-demand feature allows up to 500 data points to be recorded. The data can be recalled on the meter display with a simple press of the “RCL” button.

Data Transfer – Data can be exported to a computer for data review and storage with a USB cable and HI92000 software (both sold separately).

 

HI2300 is supplied with HI76310 conductivity probe, 12 VDC adapter, and instruction manual.

EC Specifications

EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy (@25ºC/77ºF) ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800 μS/cm)

TDS Specifications

TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy (@25ºC/77ºF) ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)

Salinity Specifications

Salinity Range 0.0 to 400.0% NaCl
Salinity Resolution 0.1% NaCl
Salinity Accuracy (@25ºC/77ºF) ±1% of reading
Salinity Calibration one point, with HI7037 calibration solution (optional)

Temperature Specifications

Temperature Accuracy ±0.4°C (±0.8°F) (excluding probe error)
Temperature Range -20.0 to 120.0 ºC
Temperature Resolution 0.1 °C
Temperature Calibration two point, at 0 and 50°C
Temperature Coefficient selectable from 0.00 to 6.00%/°C (EC and TDS only)

Additional Specifications

Electrode/Probe HI76310 platinum, four-ring conductivity/TDS probe with internal temperature sensor and 1 m (3.3’) cable (included)
Logging 500 samples, log-on-demand
Auto-off after five minutes of non-use (can be disabled)
Connectivity opto-isolated USB
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply 12 VDC adapter (included)
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
Weight 1.3 kg (2.9 lbs.)